FluidLab

FluidLab: a pump filling an elevated tank, with the pump curve, live readings and the elevation view

A virtual hydraulics bench that runs entirely in the browser. Drag reservoirs, tanks, pumps, valves, gauges and meters onto the canvas, pull pipes between their ports, and the network is re-solved instantly by EPANET 2.2 compiled to WebAssembly (epanet-js). No server, no CFD.

Try it: https://fluidlab.fly.dev · Licence: MIT · Contributing: CONTRIBUTING.md

For learning, not for design. FluidLab is a teaching bench. Its numbers are checked against hand calculations and textbook cases, but it is not verified engineering software: do not size, approve or operate real pipework, pressure vessels, steam systems, gas lines, fire protection or drainage from what it shows. See the warranty disclaimer in the licence.

npm install
npm run dev          # http://localhost:5173
npm run build        # static bundle in dist/
npm run test:engine  # solves a smoke network + every experiment rig in Node

What's in it

  • Network editor (React Flow): 34 kinds of component plus the catalogue, loose port-to-port pipes, a 5 px snap grid, 90° rotation (R), undo/redo (⌘Z / ⇧⌘Z, 100 steps, slider drags and typing coalesce into one step). What the editor can do is set out under Bench editor below, with a table of the controls.

  • Runs off the main thread: EPANET lives in a Web Worker behind a latest-wins client (no backlog while dragging a slider); falls back to the main thread if workers are unavailable.

  • Phone / touch layout: below 860 px the side panels become slide-over sheets, parts are added by tap, ports grow for fingers, and the rig re-frames above the open details sheet. Long press, double tap and box-select stand in for the right button, the double-click and the keyboard (see Bench editor).

  • Solver adapter: FluidLab model → .inp → EPANET (Darcy–Weisbach) → SI results. Pumps/valves/meters are canvas nodes that compile to EPANET links between two hidden junctions. Parts not connected to a reservoir/tank are greyed out instead of breaking the solve.

  • Educational layer: Re, friction factor, regime, valve K(opening), pump efficiency/power, NPSHa and cavitation, vapour-pressure and velocity warnings.

  • Live lab clock: quasi-steady time stepping — solve, integrate tank volumes, solve again — so tanks fill and drain while you turn valves (1× – 1200×).

  • Charts: pump curve × system curve with live operating point (system curve traced by sweeping pump speed), pipe ΔP(Q), hydraulic grade line, per-element trends.

  • Control layer (src/model/control.ts): a PLC-style scan runs once per tick — read measurements, update every block, resolve commands, move actuators — and the commands are applied when the network is compiled.

    • Signal wires are a second, non-hydraulic edge type. Green = measurement (instrument pv → controller cin); wiring one turns a tank, pressure gauge, flow meter or ΔP gauge into a transmitter. Violet = command, 0–100 % (controller sig → device ctl, or into a logic gate / lamp).
    • A command scales the device's own setting: pump speed × command, throttle-valve opening × command; anything else is on/off. Throttle valves can have an actuator stroke time.
    • Blocks: manual switch, timer, limit switch with hysteresis (level / pressure / flow by what it's wired to), PID with auto/manual, anti-windup and bumpless transfer, AND/OR/NOT gate, alarm lamp.
    • Feedback blocks only act on the lab clock, never between ticks, so a pressure switch and its pump can't chase each other in zero time.
  • Data-driven component library (src/model/catalog.ts): ~20 fittings and pieces of equipment share one fitting component. A catalogue entry picks a loss model — k (minor-loss K; reducers/expanders derive it from their two bores) or rated (datasheet Δp @ Q with exponent n and a fouling slider, sent to EPANET as a GPV head-loss curve) — plus a P&ID glyph and defaults. Adding a part is a catalogue line, not a new component type. Also from the catalogue: valve bodies (gate, globe, ball, butterfly…) with equal-%/linear/quick-opening trims and a Kv/Cv readout, and nominal pipe sizes (steel Sch 40, copper L, PVC Sch 40, PEX) that set bore, material and roughness together.

  • Storage & sources: the app integrates storage itself as volume, so tanks can be cylinders, cones, spheres or horizontal drums, and a pressure vessel (gas cushion, polytropic) is a fixed-head node whose head follows the gas law each tick. Float valve: a self-acting valve type that finds the tank on its outlet side and closes as it fills. Demand patterns: 24 h residential / commercial / industrial multipliers on the lab clock (re-solved per lab-minute). Leaky joint: a junction with an emitter, reporting loss per day.

  • Water-hammer engine (src/engine/transient.ts): a second solver — the Method of Characteristics — started from the EPANET steady state and run in the same worker. Pipes are cut into reaches of one time step (wave speeds per material, nudged so every pipe holds a whole number of reaches; friction per reach taken from the steady solution, so an undisturbed network stays exactly steady). Boundary conditions: reservoirs/tanks, junctions with demand, emitters (nozzles, sprinklers, leaks), air vessels (gas law), relief valves, stroking valves, pumps coasting down behind a check valve, and every catalogue part as a quadratic loss. Vapour pressure is a floor, flagged as column separation. Operate a valve, pump or outlet from its inspector: peak/trough, Joukowsky's ρ·a·Δv, the critical time 2L/a, pressure and flow histories anywhere, and a replay on the bench that drives gauges, pipe colours and flow particles with the recorded wave. scripts/transient-check.ts checks it against theory.

  • Domain kits — still data, not new component types. Discharge devices preset the outlet: K-factor sprinklers (sealed until their bulb breaks), hose reel, hydrant, drip emitters (plain and pressure-compensating), spray heads and rotors; Q = K·√p is exactly the solver's emitter. Pump types set the curve shape as shut-off and run-out ratios — EPANET fits H = H₀ − B·Qᶜ through three points and pumpHead() uses the same form — giving a fire pump (with the NFPA 20 churn / 150 % checks in the inspector), a steep multistage and a flat circulator. Hydronics adds boiler, radiator and a balancing-valve body; closed loops solve with the expansion vessel as the pressure reference.

  • Round-out of the catalogue: tapered reducers/diffusers, hose, a lossy three-port tee and a three-way valve (both compile to a hidden junction per port joined by lossy stubs), air valve (breaks a vacuum in the water-hammer engine), spring checks / foot valve / backflow preventers (check + pressure-breaker valve for the cracking pressure), PICV, solenoid and pinch presets, valve sizing by Kv/Cv. Pumps by table (catalogue points, or a positive-displacement pump with slip and an internal relief), efficiency chart, motor efficiency, tariff, kWh and cost; borehole, jockey and dosing presets; turbine / pump-as-turbine with recovered power. Flow-meter sensing principles with their own losses, pitot and sight glass, U-tube manometer display, totalisers, CSV export of everything recorded. Control: pump sequencer (staging with hysteresis, shared trimmed speed, lead rotation), setpoint scheduler, PID remote setpoint, S/R latch, emergency stop.

  • Gas network engine (src/engine/gas.ts): picked automatically when the working fluid is a gas (air, natural gas, nitrogen, hydrogen, CO₂). Steady isothermal compressible flow — pipes obey p₁² − p₂² = (f·L/D + K)·ṁ²·Z·R·T/A² — solved as mass balances on absolute node pressures by damped Newton (central-difference Jacobian, a starting guess propagated from the sources through regulators and compressors, friction factors refreshed in an outer loop). The same bench is re-read: reservoirs are pressure sources, pumps are compressors (pressure-ratio map, isentropic power), PRVs are regulators with droop, pressure vessels are receivers that charge and blow down on the lab clock, nozzles and leaks choke at the critical ratio. Flows are standard volumes (15 °C, 1 atm). Controls, charts and goals work unchanged. scripts/gas-check.ts checks it against hand calculations. Elevation is ignored; tees and three-way valves carry their port losses as in the liquid engine; a jet pump only costs pressure (entrainment by a gas jet is not modelled); no water hammer or thermal layer for gases.

  • Steam (src/engine/steam.ts, properties in src/model/steam.ts): pick "Saturated steam" as the fluid. The gas engine does the hydraulics with three changes — p/ρ comes from the steam table at each link's mean pressure instead of one Z·R·T, steam loads take duty ÷ h_fg(p) (so their demand depends on the pressure they get), and every pipe condenses what its surface loses (lagging thickness per pipe; conduction through mineral wool, then convection + radiation). Flows are mass flows: the flow unit switches to kg/h (t/h, lb/h) with the fluid. The steam layer then follows the condensate: each pipe's share travels downstream to the first working steam trap (or drip leg next to the main); what reaches a load instead is reported as carry-over, what reaches nothing is flagged as a water-hammer risk. Traps have an orifice capacity (derated for flashing) and a condition: a failed-open trap is a choked orifice blowing live steam, priced per plant year; a blocked one drains nothing. Reservoirs are boilers (feedwater temperature, efficiency, steam cost); throttling valves report the superheat they leave; loads warn when saturation temperature is below the process temperature + 5 K; loads and traps report flash steam at their return pressure. The thermal overlay shows steam temperature; the overview gives the heat balance. Condensate return: a pipe can carry "condensate, returning" instead of steam (anything piped to an open tank does so from the start), and the tank is the vented receiver. Each trap's and load's condensate is routed down the tree to the receiver; every line is a homogeneous two-phase flow whose flash fraction follows from the enthalpy it left the steam space with, so its velocity and friction are those of the flash steam; lifts cost 950·g·Δz. The pressure that builds up the line is the back-pressure the traps and loads really discharge against — it sets trap capacity and flash, and a load whose return stands as high as its steam space is reported as stalled. The receiver keeps the liquid and vents the flash; what comes home raises the boiler's feedwater temperature and cuts its heat input. Saturated steam only: no superheated mains, no pumped return or pressurised flash recovery, no warm-up loads, no control valve on the loads. scripts/steam-check.ts checks tables, mass balance, Darcy drop, choked trap and PRV against hand calculations.

  • Open-channel engine (src/engine/channel.ts, hydraulics in src/model/openchannel.ts): any conduit can be switched from "pipe, flowing full" to "open channel" (rectangular, trapezoidal, V or part-full circular; Manning n from a lining catalogue), and anything connected to a channel part is a reach from the start. Bed levels come from the node elevations. Steady gradually-varied flow: reaches are oriented towards the nearest outfall and get their discharge from continuity; a subcritical standard-step pass runs upstream from every downstream control (free drop, fixed tailwater, normal depth, weir, gate, junction level), a supercritical pass runs downstream from every upstream control (critical inlet, gate vena contracta, weir toe), and at each station the profile with the larger specific force wins — the hand-over is the hydraulic jump (HEC-RAS's mixed-flow method). Forks are iterated until both branches agree on the level at the fork. Parts: inflow, weirs (sharp-crested/Rehbock, contracted/Francis, V-notch, Cipolletti, broad-crested, Parshall flume; Villemonte when drowned; a pv flow output), sluice gate (free and drowned/Henry; takes a controller's command), outfall. Readings give yₙ, y꜀, slope class, Froude range, the profile name (M1, S2, "M3 → jump → M1" …), jump depths and the power it dissipates; the inspector draws the water surface against bed, normal and critical depth along the main stem; warnings cover overtopping, scour and pipes running full. Pipework and channels exchange water: the pipe side is solved first, then the channels. An outlet has a second, discharge-side port — run a reach from it and the channel carries whatever the outlet delivers. A tank or open reservoir is a lake to the channel engine: upstream, it gives the flow that makes the specific energy at the head of its channel equal its level above the sill (critical at the lip on a steep channel, uniform flow on a long mild one — found by bisection around the whole channel solve); downstream, its level is the tailwater. The sill level is a property of the tank or reservoir. Tanks add up what pipes and channels give and take, so the lab clock fills and drains them correctly. A junction can carry a step down in the bed; forks of any number of branches settle on one water level; a gate whose lip the normal depth just reaches holds the surface at the lip.

  • Unsteady channel flow (src/engine/wave.ts): the "live flow" switch marches the channels through lab time with the Saint-Venant equations — finite volumes carrying area and discharge, HLL fluxes (bores and jumps capture themselves), hydrostatic reconstruction for the bed slope (still water stays still), implicit Manning friction. Junctions are small ponds exchanging water with the reach ends round them; weirs and gates pass what their own law allows, drowned or free, either way; inflows, outfalls, lakes and outlet feeds are boundary states. It starts on the steady solution, so nothing moves until something changes: a storm pulse on a timer, a gate, a lake level. scripts/wave-check.ts checks that it holds the steady state, conserves water, settles on the new steady state after a change and moves a disturbance at about u + c. Tanks on the channels fill and drain at the live rate. scripts/channel-check.ts checks it against hand calculations.

  • Jet pump (ejector): three ports, and both of its internal links depend on heads elsewhere in the network — the nozzle sees motive − suction, the entrainment curve scales with motive − discharge — which no single EPANET element can express. The engine wraps EPANET in a relaxed fixed-point: solve, read those heads, rebuild the nozzle's K and the entrainment pump curve from Cunningham's N(M, R) model, solve again (settles in a handful of passes, ~10 ms). Inspector shows M, N, R, efficiency M·N and the characteristic with the operating point. In the water-hammer engine tees, three-way valves and jet pumps keep their anatomy — a hub whose ports each reach it through their own loss, solved for the hub head that balances them every time step; the jet pump's nozzle loss and entrainment head are frozen at their steady values.

  • Thermal layer (src/engine/thermal.ts): once flows are known, water temperature is carried round the loop — mixed at junctions, reset by a boiler, given up by emitters (NTU model against a constant room temperature). Shows as a "Thermal" pipe-colour overlay with temperatures and heat duty per part. It switches on for a boiler, a heated or pre-warmed tank, or a reservoir that is not at 15 °C. Pipes lose heat only once they are told what they are wrapped in (bare … 100 mm wool; the default leaves loss out), and a boiler can be given a maximum output.

  • Transient heat transfer (src/engine/heat.ts): the "live heat" switch in the top bar marches those temperatures through lab time instead of showing where they settle. Hydraulics stay quasi-steady; heat rides on the flows. Every pipe is a row of cells (≈1.5 m) advected upwind and implicitly — stable at any step, sub-stepped to a Courant number near one — carrying the water and the pipe wall it has to warm, and leaking to the room through its lagging. Junctions mix; dead water remembers its temperature; a tank is one stirred volume with an optional immersion heater on a thermostat and a standing loss; boilers and emitters have thermal mass, so they answer with a lag. The pipe overlay gets one colour stop per cell, so a hot front can be seen travelling; the inspector draws temperature along the pipe and its trend; a thermometer (pv output in °C) gives switches and PIDs a temperature to act on; the overview shows where the heat is going right now (in, to the rooms, lost, soaking into water and metal). Run long enough it lands exactly on the steady layer (scripts/heat-check.ts checks that, the plug-flow delay of a dead leg including its copper, and a cylinder warming at P/ρcV). A tank can be stratified: ten stacked layers, its top port drawing from the top and the others from the bottom, plug flow between them, a heater at a set height, and convective turnover wherever warm would sit under cold — so a cylinder delivers nearly its whole volume hot. Limits: first-order upwind smears sharp fronts, rooms are at fixed temperature, water properties do not change with temperature, and liquids only.

  • Sources: a reservoir is an open surface, a mains connection quoted in pressure, or a well whose pumping level is drawn down in proportion to yield (a head-loss curve between the aquifer and the pumping node). Tanks can overflow at the rim (spill reported) instead of shutting their inlet; the float valve has an altitude-valve mode (latched shut / open); household fixtures (taps, shower, WC, appliance) are K-factor presets; a burst main is a dormant 40 mm leak that can be ruptured as a water-hammer event.

  • Relief valve: a PSV venting to an atmospheric reservoir through a stub pipe — holds its set pressure by lifting just far enough.

  • Event sequences: a control block holding a list of timed steps — at t seconds take this wired device to that command, optionally ramping there over so many seconds ("start the pump at 5 s, open the valve over 60 s, stop everything at 10 min"). It is wired like any controller; each wire gets its own command, a device is left as configured until its first step, a new step starts from wherever the last ramp had got to, and the list can repeat. The command is a pure function of lab time, so the scan stays idempotent. It works with everything on the lab clock — tanks, live heat, live flow — but not inside a water-hammer run, which still operates one device. scripts/sequence-check.ts checks the step and ramp arithmetic and the per-wire commands.

  • Shareable links (src/share.ts): "Share" copies a URL that is the rig — the project JSON, deflated (CompressionStream, plain base64 where that is missing) and base64url-encoded into the fragment, #rig=…. A fragment is never sent to a server, so nothing is uploaded and nothing can expire. Opening one loads the rig (with its fluid, units, clock speed and live-heat / live-flow modes) and then drops the fragment, so a reload keeps your edits rather than the link's copy. Every built-in rig fits in under 2,000 characters; scripts/share-check.ts round-trips them all. If the clipboard is not available the link is shown instead.

  • Small follow-ups

    • Parshall submergence: a flume keeps its free-flow rating up to its submergence limit (50 / 60 / 70 % by throat size) and then loses ISO 9826's correction, taken from the limit on so the rating stays continuous (the standard gives it for 1–8 ft flumes; it is used for the small ones too). Steady and unsteady engines share it.
    • Overflow spillways: a tank with an overflow meets a channel at its rim, and once full it spills whatever the pipes still bring into that channel — without the spill counting as the tank's own loss.
    • Pumped condensate return: a receiver can have a condensate pump. The traps then only reach the vented receiver; the pump takes the lift and the run to a feed tank (single-phase Darcy, head, power), and warns when the near-boiling condensate has too little height over it (NPSH).
    • Steam accumulator: a pressure vessel on steam stores energy in saturated water, so its pressure follows M_w·(dh_f/dp)·dp/dt = ṁ_in·h_fg instead of the ideal-gas receiver law. The water mass is taken as constant.
    • Sequence time units: a sequence's steps can be typed and charted in seconds, minutes or hours.
  • Second-round engine work

    • Pipes running full: a circular reach carries a Preissmann slot — a hair-line slit along the crown (0.2 % of the diameter) — so its "depth" can rise above the crown as pressure head while the area and wetted perimeter stay those of the full bore. The steady and the unsteady channel engines both then handle a surcharged culvert or sewer with the equations they already had; the profile reads "full" and the head over the crown is reported.
    • Surge sequences: a water-hammer run can operate any number of devices, each with its own history of moves (every move starts where the last left it; a pump trips when first taken to zero). An event sequence block can be played through the pressure-wave engine from its inspector.
    • Gas ejector: in a gas network a jet pump entrains. Its motive nozzle is a compressible orifice blowing into the suction chamber (it chokes), and the entrained flow is what Cunningham's N(M) allows against the pressure rise asked of it, with M the mass-flow ratio (same gas, same chamber pressure and temperature).
    • Gas transients (linepack): "live gas" adds a storage term V/(ZRT)·(p − p_old)/dt to the mass balance of every node that pipes end at — backward Euler inside the same Newton solve, so it conserves gas exactly and is stable at any clock speed. Each time the solver answers, its pressures become the memory for the next step. Lumped storage, quasi-steady momentum: right for minutes-long events (outages, demand swings), not for acoustic waves.
    • Superheat in steam mains: enthalpy is carried along the flows. A boiler can superheat, a throttling valve keeps enthalpy, and a pipe must take the superheat out (losing heat faster while it lasts) before it condenses anything; the flows are re-solved with the condensate that really forms. Density and the loads' steam demand still assume saturation.
    • Water that thins as it warms: in heated rigs every pipe's friction factor is re-evaluated at its own water temperature (Vogel viscosity, Kell density) and fed back as an equivalent length until flows and temperatures agree — 22 % less head loss at 80 °C in a small copper run. Uses the settled temperatures, not the live ones; buoyancy (thermosiphon) is not modelled.
    • Two bugs fixed on the way. The solver thread was sent a model rebuilt field by field, which silently dropped the lab time — so daily demand patterns never moved in the app, though every script (which calls the engine directly) passed; it now passes every field. And the unsteady channel engine's Manning term divided by A² instead of A, over-stating friction in sections under 1 m². Weir-controlled profiles hid it; a uniform-flow check now guards it.
  • Refinements

    • Pipes can tap a channel: a joint with both pipes and reaches on it gives the pipe side the channel's water level as a fixed head, and the channel loses what the pipes take (a pump lifting from a canal); the two engines go round a few times until they agree.
    • Steam loads have a control valve: a load fraction (which a controller can drive) throttles the steam space down towards the process temperature — steam demand, flash and the stall point (the load below which the space is no hotter than the back-pressure allows, so it floods) follow. Trap types differ in capacity, working steam loss, back-pressure tolerance and whether they hold condensate back; every pipe reports its warm-up condensate and traps are checked against the start-up rate; flash in a return line is taken at its mid-line pressure.
    • Heat: a boiler takes a controller's command; an emitter can model the room it heats (mass, loss to an outside temperature) and offers that temperature to a thermostat; live readings show what reaches the room, not what the radiator's own metal is soaking up.
    • Gas risers: gauge pressure is measured against the air outside at the same height, so a gas lighter than air gains pressure going up (+4.4 Pa/m for natural gas) and a heavier one loses it.
    • Event sequences can wait for a signal on their input (start on it, or run only while it is on), pick each repeat up where the last one ended, and chart any number of devices three to a plot.
  • Searchable palette with collapsible groups; catalogue parts travel as kind:variant.

  • 58 experiments with briefs and auto-checked goals (gravity feed → Venturi/orifice meters → level switch, constant-pressure PID booster, flow loop with a motorised valve → fittings, clogging strainer vs NPSH, relief valve → pressure vessel short-cycling, night flow & leakage, tank shapes, float valve → sprinkler branch line, fire-pump acceptance test, irrigation lateral uniformity, balancing a heating loop → water hammer, surge vessel, pump trip → standpipe, booster set with a sequencer, jet pump → compressed-air main, gas service regulator, choked blowdown → uniform flow, backwater behind a weir, sluice gate & hydraulic jump, spillway chute → sizing a steam main, lagging and drip traps, reducing station and a blowing trap → waiting for hot water, warming up a heating loop, lagging a hot-water main → pumping into a canal, a canal out of a lake → a flood wave down a river, a cylinder that stratifies, bringing the condensate home → starting a pump station, a room thermostat, holding a canal level, riding through on linepack). scripts/control-sim.ts runs the loops closed in Node to prove each control goal is reachable and not trivially met.

  • Differential instruments: a ΔP gauge tapped through zero-flow sensing lines (compiled as a closed link), and a Venturi/orifice element. EPANET only tracks piezometric head, so the throat differential is computed from Bernoulli in the educational layer and only the permanent loss is handed to the solver as a minor-loss K.

  • Units engine: SI stored, anything displayed (kPa/bar/psi/m H₂O, L/min/GPM/m³/h, mm/in, W/hp …).

  • Fluids: water at 20/60/90 °C, glycol mix, diesel, light oil.

  • Autosave to localStorage, JSON project save/open.

  • Bench editor: built for laying a rig out quickly and changing it without starting again.

    • Moving around and selecting: a drag on the empty bench draws a selection box, and picks every part it touches; the bench itself is moved with the middle button or with Space held, and the wheel zooms. Parts snap to a 5 px grid. The slider at the foot of the bench fades the grid from hidden to bright, and is remembered in the browser.
    • Cut a part into a pipe: drop a part from the list on a pipe, or drag a loose part over one — the pipe lights up, and on release it is split in two. Both halves keep the pipe's properties and share its length; the part is turned to face along the run and its ports are set on the pipe's line. Weirs and gates only go into channels. One undo takes the whole thing back.
    • Copy, paste, duplicate (⌘C ⌘V ⌘D), with the pipes and signal wires between the copied parts; paste lands at the pointer, and works across tabs. ⌘A selects everything.
    • Move a pipe end: select a pipe or wire and drag either end to another port. A pipe end only goes to a fluid port, a wire end only to a signal port.
    • Right-click menu on parts, pipes and the empty bench; double-click a part to set its key value (valve opening, pump speed, tank level, gate opening, …) where it stands; double-click the bench or press / to add a part by typing its name.
    • Routing: a selected pipe between facing ports has a handle on its middle run — drag it aside, double-click it to reset. Where a level pipe crosses an upright one it hops over it. Labels sit beside the longest straight run, clear of crossings, and show only the flow until the pipe is hovered or selected; they can be hidden from the bench menu.
    • Alignment: a dragged part snaps its port line and its centre to its neighbours', with a guide showing which. The pull lets go within one grid step, so a part can still be set just off its neighbour's line. With several parts selected, a bar offers align (ports, edges, centres) and even spacing.
    • Elevation view: a side view under the bench, lined up with it — each part at its elevation, the pipework between, tank and reservoir water columns, and the hydraulic grade line. Drag a part up or down to change its elevation.
    • Port hints: while a pipe or wire is being pulled, the ports it may end on stand out and the rest step back; a refused connection says why; resting on a port names it.
    • Warnings frame the part or pipe they are about when clicked, and the list opens in full.
    • Touch screens: a long press opens the menu a right-click would (on a part, a pipe or the bench); a double tap does what a double-click does (set a part's key value — docked across the bench on a phone — or add a part by name). One finger moves the bench; the box-select button switches it to drawing a selection box, and two fingers still pinch and pan. A delete button appears with a selection. With a pipe selected, a part picked from the list is cut into that pipe, since a finger cannot drag from the list. Pipe-end, bend and elevation handles are larger.
    • Groups and assemblies: ⌘G groups the selected parts — they are framed, named, and move, copy and delete as one. "Save" keeps a selection, with its pipes and wires, in the parts list (in this browser) for other rigs.
    • Layout is not hydraulics: positions, pipe routes, groups and the grid setting never reach the solver, so tidying a rig does not re-solve it. Every change to the rig itself goes through undo.
    • Left out: a group cannot be folded into a single block; only a pipe's middle run can be moved, not free waypoints; signal wires do not hop, and at a crossing it is always the level pipe that does; saved assemblies stay in one browser and are not part of project files or share links; the editor has no automated tests — it is checked by hand in the browser, and the touch gestures with simulated touches only.
    To do this Mouse and keyboard Touch
    Add a part drag or click it in the list · / or double-click the bench, then type tap it in the list · double tap the bench
    Cut a part into a pipe drop it on the pipe · right-click the pipe → Insert select the pipe, then tap the part in the list · long press the pipe → Insert
    Lay a pipe or wire pull from a port to another port the same
    Move a pipe end select the pipe, drag its end to another port the same
    Move a pipe's middle run select the pipe, drag the round handle; double-click it to reset the same; reset it from the pipe's menu (Straighten the route)
    Select click · drag a box on the bench · ⌘-click adds · ⌘A all tap · box-select button, then drag
    Move the bench middle button, or Space and drag · wheel zooms one finger · pinch zooms
    Menu right-click a part, a pipe or the bench long press
    Set a part's key value double-click the part double tap the part
    Rotate · delete R · ⌫ menu · delete button
    Copy · paste · duplicate ⌘C · ⌘V · ⌘D menu
    Group ⌘G, or the bar shown with several parts selected the bar, or the menu
    Undo · redo ⌘Z · ⇧⌘Z or ⌘Y the arrows in the top bar
    Elevation view the Elevation button, or the bench menu the bench menu

Privacy

There is no server side, no account and no analytics. A rig is kept in the browser's local storage, in a project file you save, or inside the #rig= part of a share link — which browsers do not send to the server, and which the app drops from the address bar once the rig has loaded. Saved assemblies, the clipboard and the grid setting are local storage too.

Deploy (Fly.io)

FluidLab is a static bundle, so the image is just a Node build stage + nginx (Dockerfile, deploy/nginx.conf). Machines auto-stop when idle and wake on the first request.

fly launch --copy-config --no-deploy   # once: creates the app — choose a unique name and your region
fly deploy                             # build remotely and ship

Layout

src/model/     types + defaults, units, physics, openchannel, steam (pure, SI)
src/engine/    inp.ts (compile) · epanet.ts (steady engine) · gas.ts (gas engine) · steam.ts (steam layer) · channel.ts + wave.ts (open channels, steady and unsteady)
               transient.ts (water-hammer engine) · thermal.ts (steady heat layer) · heat.ts (transient heat)
               worker.ts + client.ts (threading)
               analysis.ts (curves, grade line)
src/experiments.ts   rig builder + the experiment catalogue
src/store.ts   zustand store, solve scheduling, tank time-stepping, persistence
src/ui/        nodes, animated pipe edge, inspector, charts, top bar, sidebar
src/editor.ts  bench editing commands (splice, clipboard, align, groups) · src/ui/route.ts pipe routing and hops
               src/ui/EditorLayer.tsx menus, guides, elevation view · src/ui/editorState.ts editor-only state

HydraulicEngine is the seam solvers plug into: EPANET, the gas engine and the open-channel engine all sit behind it today, with steam as a layer on the gas engine and heat (steady or marched through time) as a layer on the liquid one.

Contributing

Bug reports are most useful as a saved rig plus the number you expected and where it comes from. Code changes to a solver need a check in scripts/ against a hand calculation or a published result. The details are in CONTRIBUTING.md; conduct is covered by CODE_OF_CONDUCT.md, and vulnerabilities go through SECURITY.md, not public issues.

Licence and credits

FluidLab is © 2026 Andre Paquette and released under the MIT licence.

The pressurised-pipe solver is EPANET 2.2 — written at the U.S. EPA, maintained by Open Water Analytics — compiled to WebAssembly by epanet-js. The bench is built on React Flow, React and zustand, and set in Space Grotesk and JetBrains Mono. Their licences are summarised in THIRD_PARTY_NOTICES.md and reproduced in full in public/licenses.txt, which ships with the site at /licenses.txt. FluidLab is not affiliated with or endorsed by any of them.

About

A virtual fluids lab in the browser: build a rig of pipes, pumps, valves and tanks and watch it solve live — water networks (EPANET in WebAssembly), gas and steam, open channels, water hammer, heat and control loops. 58 guided experiments. No server, no install.

Topics

Resources

Code of conduct

Contributing

Security policy

Stars

1 star

Watchers

0 watching

Forks

Releases

Packages

Contributors

Languages