New SHA-256:6be4fb03abc44be59b9237f9942a33e2d57f4288fb6d77181921bb278daa9659
Detected: 2026-09-21T06:50:03+00:00
Review
Read the new document and note what changed (registers renumbered,
parameters added, scaling corrected).
Cross-check against the registers/parameters nibe_local reads.
If the driver is affected, open a fix and bump its version;
otherwise close this issue.
Detection is a raw-byte hash: the file's bytes moved. That can be a
genuine content change or just rebuild churn in the PDF metadata —
this issue is a prompt to look, not proof the registers changed.
Reviewed the current nibe-n.pdf (SHA-256 6be4fb03..., 846072 bytes, matching this issue's hash) against drivers/lua/nibe_local.lua.
The document's visible content is unchanged from the revision issue #121 already audited: same "Latest revision: 2026-09-07", 64 pages, same newest entry (NIBE S-series v4.13.12 — PV-surplus menu option, EEBUS/OHPCF, myUplink power tile, S735/S735C additions, RMU S40 bump, assorted comms/valve fixes). No entry newer than 2026-09-07 appears anywhere in the extracted text. The byte-size delta (857227→846072 bytes) with identical rendered content points to a PDF rebuild/metadata churn (fonts/compression), not a content edit.
Re-checked #121's fixed-ID list against the current file by grepping the full 64-page text: 1801 (power), 22130 (used power), 11/158/4 (BT6/BT50/BT1 temps), 28393/28392 (energy consumed/produced), 781 (degree minutes) — verified against an S735 — plus the two Solar-PV-feed Modbus registers 2107/2109 used by the write path added in #46. None of these ten numbers appear anywhere in the current document, and the new top entry (immersion-heater-only PV surplus, 4.2.2) doesn't mention or touch 2107/2109.
Activity
frahlg commentedon Sep 21, 2026
Reviewed the current
nibe-n.pdf(SHA-2566be4fb03..., 846072 bytes, matching this issue's hash) againstdrivers/lua/nibe_local.lua.The document's visible content is unchanged from the revision issue #121 already audited: same "Latest revision: 2026-09-07", 64 pages, same newest entry (NIBE S-series v4.13.12 — PV-surplus menu option, EEBUS/OHPCF, myUplink power tile, S735/S735C additions, RMU S40 bump, assorted comms/valve fixes). No entry newer than 2026-09-07 appears anywhere in the extracted text. The byte-size delta (857227→846072 bytes) with identical rendered content points to a PDF rebuild/metadata churn (fonts/compression), not a content edit.
Re-checked #121's fixed-ID list against the current file by grepping the full 64-page text:
1801(power),22130(used power),11/158/4(BT6/BT50/BT1 temps),28393/28392(energy consumed/produced),781(degree minutes) — verified against an S735 — plus the two Solar-PV-feed Modbus registers2107/2109used by the write path added in #46. None of these ten numbers appear anywhere in the current document, and the new top entry (immersion-heater-only PV surplus, 4.2.2) doesn't mention or touch 2107/2109.No impact on
nibe_local. Closing as not-planned.Generated by Claude Code