94 changes: 85 additions & 9 deletions docs/architecture/concepts/failure-domains.md
Original file line number Diff line number Diff line change
Expand Up @@ -76,12 +76,40 @@ a same-domain secondary path, and its tertiary path is still guaranteed to be cr

## Failure Domains and Erasure Coding Schemes

The number of failure domains should match the data protection goal:
The number of failure domains decides two things: whether a cluster can activate with failure domains enabled,
and how much simultaneous node or domain loss it absorbs afterward.

| Goal | Recommendation |
|---------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------|
| Survive one full domain outage | At least `parity chunks + 1` distinct failure domains |
| Survive one full domain outage plus one further node or drive failure elsewhere | Erasure coding scheme with two parity chunks (e.g., `1+2`, `2+2`) and at least as many domains as data chunks |
!!! important
Fresh activation requires **at least `parity chunks + 2` distinct failure domains**. Two domains are never
enough, at any parity-chunk count. With only `parity chunks + 1` domains the layout has no spare host left, so
the very next node addition or removal strands a failover path with nowhere valid to go. Below the minimum,
activation is refused. Either failure domains have to be disabled, or hosts in further domains have to be
added first. A reactivation of an existing layout is only warned about, never blocked.

A stripe consists of `data chunks + parity chunks` chunks, and placement spreads them as evenly as the available
domains allow. How much loss an activated cluster absorbs follows from that spread:

- With **`data chunks + parity chunks` domains or more**, every domain holds at most one chunk of a stripe. The
**complete loss of up to `parity chunks` domains** at once is then tolerated. This is the same guarantee as
running without failure domains, scoped to whole domains instead of individual nodes.
- With **fewer domains than `data chunks + parity chunks`**, at least one domain holds more than one chunk. Each
domain contributes at most `⌈(data chunks + parity chunks) / domains⌉` to a risk budget of `parity chunks`. A
domain that already has that many nodes down has spent its whole contribution, so further nodes in the same
domain cost nothing extra. A node in a different domain spends a fresh share of the same budget. Any combination
is tolerated while the summed contributions stay within `parity chunks`.

| Domains | 1+1 | 2+1 | 4+1 | 1+2 | 2+2 | 4+2 |
|------------|-----------------|-----------------|-----------------|-----------------|-----------------|-----------------|
| 2 or fewer | cannot activate | cannot activate | cannot activate | cannot activate | cannot activate | cannot activate |
| 3 | 1 whole domain | 1 whole domain | 1 node total | cannot activate | cannot activate | cannot activate |
| 4 | 1 whole domain | 1 whole domain | 1 node total | 2 whole domains | 2 whole domains | 1 whole domain |
| 5 | 1 whole domain | 1 whole domain | 1 whole domain | 2 whole domains | 2 whole domains | 1 whole domain |
| 6+ | 1 whole domain | 1 whole domain | 1 whole domain | 2 whole domains | 2 whole domains | 2 whole domains |

"1 whole domain" means every node of one domain, whatever its size, can go down at once and the cluster stays
available. The same budget spent as individual nodes, one per domain across that many domains, is tolerated
identically. A cell short of a whole domain (`4+1` on three or four domains) means only that many individual nodes
anywhere in the cluster, not a domain's worth.

The high-availability journal requires at least **four** journal copies on failure-domain clusters (instead of
three), even with a single parity chunk. With three copies and two domains, one domain would hold two copies and
Expand All @@ -93,14 +121,62 @@ A host's failure domain cannot be changed while the host is part of the cluster.
requires removing the node, restoring the domain balance, and re-adding it with the new failure-domain label. This
prevents accidental topology changes that would silently invalidate the placement of existing data.

## When to Remove a Node

Node removal takes a host out of the cluster permanently. It serves two purposes: retiring a **failed host** that
is not coming back, and **shrinking** a cluster that has more storage nodes than it needs. A node that is offline
or unreachable can still be removed, so removal is the intended way to resolve a dead host rather than a last
resort.

Leaving a dead node in the cluster is the case to avoid. Domain balance counts every host that has not been
removed, whatever its state, so a dead node still occupies its domain's slot while serving nothing. The cluster
stays degraded, and the balance rules then close the door behind it:

- The first dead host in a domain can still be removed. Its domain drops to one host below the others, which the
±1 rule permits.
- If a **second** host in that same domain fails before the first is removed, only one of the two can go. Removing
the second would leave that domain two hosts below the others and, on a three-host domain, below the two-host
floor. Admission refuses it.

At that point the degradation cannot be cleared by removal at all, and hosts have to be added before the cluster
can be repaired. Remove a failed host promptly, then restore the balance one of two ways:

- **Add a replacement host** in the same failure domain, returning the split to what it was.
- **Rebalance** by removing hosts from the other domains until every domain is within ±1 again.

The same reasoning applies to planned shrinking: reduce the domains evenly rather than emptying one, so the
cluster never sits closer to the floor than it has to.

A removal is admitted only when all of the following hold:

- The node holds **no volumes and no snapshots**. Migrate or delete them first; removal does not move them.
- The resulting per-domain host split stays within the **±1 rule** and keeps at least **two hosts per domain**.
- Every failover path the node hosts for another volume store has a valid host-disjoint target to move to, after
the splice fallback described in [The Placement Contract](#the-placement-contract).
- The cluster has enough node headroom above `data chunks + parity chunks` to absorb the loss, counting hosts that
are already not online.

## Journal Copy Replacement on Removal

Removing a node affects every journal redundancy set that referenced the departed node's journal copy. One
replacement member is picked per set, and every host running a local instance of that set applies the same
decision, so the membership stays identical on all of them.

The replacement is picked with the same domain-balance goal as the original placement. A candidate from the
**same failure domain** as the departed node is preferred, which leaves the set's domain distribution as it was
instead of reshuffling it. The preference is best-effort, not a requirement: if no same-domain candidate is free, a
cross-domain one is used, and the removal is never blocked over it. Failover-path relocation works in the opposite
direction (see [The Placement Contract](#the-placement-contract)), where a cross-domain target is sometimes
mandatory and the removal is refused without one.

## Recovery Behavior

Failure domains also change how the cluster recovers from large outages:

- An outage confined to one domain (up to and including every node of the domain) keeps the cluster **degraded
but serving**. The cluster is not suspended.
- With two parity chunks, the cluster additionally tolerates the loss of one entire domain **plus** one further
node or device outage in exactly one other domain.
- An outage confined to one domain keeps the cluster **degraded but serving**, as long as that domain's
worst-case contribution fits the parity budget of the sizing table above. The cluster is not suspended.
- With two parity chunks and at least `data chunks + parity chunks` domains, the loss of one entire domain
**plus** one further node or device outage in exactly one other domain is tolerated as well.
- When a whole domain returns from an outage (for example, after a rack power loss), its nodes are restarted **in
parallel** instead of strictly one-by-one, substantially shortening the recovery of large domains.

Expand Down
11 changes: 11 additions & 0 deletions docs/kubernetes/operations/cluster/failure-domains.md
Original file line number Diff line number Diff line change
Expand Up @@ -169,6 +169,17 @@ In practice, this means workers are added in whole rounds. On a balanced cluster
and the next worker has to go to a different one. The full rules are in
[Failure Domains: Balance Rules](../../../architecture/concepts/failure-domains.md#balance-rules).

Removal is meant to take a worker out of the cluster, either because it has failed for good or because the cluster
is being shrunk. A failed worker that is left in place still counts toward its domain's host total while serving
nothing, and if a second worker in the same domain fails before the first is removed, only one of the two can be
removed at all. See
[When to Remove a Node](../../../architecture/concepts/failure-domains.md#when-to-remove-a-node).

Removing a node also triggers journal-copy replacement on every journal redundancy set that referenced its
journal copy. Failover-path relocation can require a cross-domain target. The journal replacement instead prefers
a candidate from the departed node's own failure domain, which leaves the set's domain distribution as it was. See
[Journal Copy Replacement on Removal](../../../architecture/concepts/failure-domains.md#journal-copy-replacement-on-removal).

For the mechanics of adding the workers themselves, see
[Expanding a Storage Cluster](../scaling/expanding-storage-cluster.md), and for taking one out,
[Removing a Storage Node](../storage-nodes/removing-a-storage-node.md).
Expand Down
16 changes: 15 additions & 1 deletion docs/non-kubernetes/operations/cluster/failure-domains.md
Original file line number Diff line number Diff line change
Expand Up @@ -162,10 +162,24 @@ before any change is made.

## Removing a Storage Node

Removal is meant to take a host out of the cluster, either because it has failed for good or because the cluster is
being shrunk. It is not a way to park a broken host: a failed host that is left in place still counts toward its
domain's host total while serving nothing, and once a second host in the same domain fails, only one of the two can
be removed at all. Remove a failed host promptly and then restore the balance. See
[When to Remove a Node](../../../architecture/concepts/failure-domains.md#when-to-remove-a-node).

Node removal applies the same balance rules (±1, minimum two hosts per domain). In addition, the failover paths
hosted by the node being removed are relocated to other nodes. If the path being relocated is the only
cross-domain path of its volume store, the replacement node **must** be in a different failure domain than the
primary. If no such node exists, the removal is refused.
primary. An idle host in the required domain is looked for first. If none is free, the path is spliced into an
already-formed pairing instead: a host that currently carries another node's failover path is taken over, and that
path is moved onto the primary being repaired. Only when neither option exists is the removal refused.

Node removal separately triggers journal-copy replacement on every journal redundancy set that referenced the
departed node's journal copy. This works in the opposite direction from failover-path relocation. The replacement
prefers a candidate from the departed node's own failure domain, which leaves the set's domain distribution as it
was instead of reshuffling it. The preference is best-effort, not a requirement, and never blocks the removal. See
[Journal Copy Replacement on Removal](../../../architecture/concepts/failure-domains.md#journal-copy-replacement-on-removal).