Skip to content

Preserve camera calibration and valid capture timestamps - #5

Open
xia-chao wants to merge 1 commit into
mainfrom
fix/camera-info-and-startup
Open

xia-chao wants to merge 1 commit into
mainfrom
fix/camera-info-and-startup

Conversation

@xia-chao

Copy link
Copy Markdown
Contributor

Changes

  • Allow uncalibrated capture when a default calibration file is missing, and pass explicit calibration URLs through unchanged.
  • Preserve calibrated dimensions and refresh CameraInfo after setting calibration.
  • Avoid checking frame count in continuous mode and support the legacy ExposureTimeAbs feature.
  • Reject non-finite timestamp offsets and preserve a valid capture timestamp when an offset falls outside the ROS time range.

Validation

  • Linux build passed with ROS 2 Jazzy and Aravis 0.8.30.
  • Verified actual frames from an isolated GigE camera with missing, blank, package, and invalid calibration paths.
  • Verified 64 × 48 capture with 2048 × 2048 calibration, live setting of calibration, a requested 2345 µs exposure, and both valid and invalid timestamp offsets.

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Labels

None yet

Projects

None yet

Development

Successfully merging this pull request may close these issues.

1 participant