  • Record Aravis device control loss before shutting down the ROS context.
  • Return a failure exit code from both standalone camera drivers after a control loss so process supervisors can detect the failure.

Validation

  • Built both ROS 2 Jazzy packages on Linux. The driver test run reported 80 results with 0 errors, 0 failures, and 22 skips.
  • With the Aravis GigE simulator, received a 512 × 512 Mono8 ROS image before stopping the simulator. The control-loss log was present and the driver exit status changed from 0 to 1.
  • After receiving the same image with the simulator still running, SIGINT stopped the driver with exit status 0 before and after the change. The USB3 driver was built without a hardware test.