Robot Calibration Workbench logo

Robot Calibration Workbench

Calibrate the spatial relationship between an industrial robot and its camera.

Robot Calibration Workbench is a C++ toolkit for robot vision calibration. It covers camera intrinsics, target-based pose estimation, hand-eye calibration, and the analysis needed to decide whether a calibration result is usable.

The algorithms live in standalone CMake libraries that do not require ROS. The workspace build and the Qt applications are optional layers on top. Datasets for the hand-eye workflow ship with the repository, so the examples run without a robot or a camera.

Components

Directory Contents
core/ Data types and shared geometry used by every other component.
optimizations/ Solvers for camera intrinsics, PnP, hand-eye, and kinematic parameters.
target_finders/ Target detection. The bundled implementation uses OpenCV.
analysis/ Reprojection checks, pose differences, and uncertainty analysis.
gui/ Qt applications for camera intrinsic and hand-eye calibration.
examples/ Runnable examples, including a hand-eye workflow on bundled data.

Checkerboard target

Use this target finder with a plain checkerboard in a camera calibration dataset. Specify the number of inner corners across each dimension and the spacing between corners in meters. Use images in which the complete checkerboard is visible.

target_finder:
  type: ChessboardGridTargetFinder
  rows: 5
  cols: 7
  spacing: 0.03

Requirements

  • Linux with a C++17-capable toolchain and CMake.
  • OpenCV for the target finder and the examples.
  • Qt for the GUI applications.
  • ROS 2, vcs, colcon, and an initialised rosdep for the workspace build. The core libraries also build as a plain CMake package without ROS.

Build

Create a workspace, pull the declared dependencies, and build with colcon:

mkdir -p calibration-ws/src
cd calibration-ws
git clone https://github.com/cpp-hardtech/robot-calibration-workbench.git src/calibration_workbench
vcs import src < src/calibration_workbench/dependencies.repos
rosdep install --from-paths src --ignore-src -r -y
colcon build

The GUI applications and the examples are controlled by CALIBRATION_WORKBENCH_BUILD_GUI and CALIBRATION_WORKBENCH_BUILD_EXAMPLES in the top-level CMakeLists.txt; both default to ON. Testing and clang-tidy are behind CALIBRATION_WORKBENCH_ENABLE_TESTING and CALIBRATION_WORKBENCH_ENABLE_CLANG_TIDY.

ROS camera calibration YAML

Use calibration_workbench::fromROSFormat(YAML::LoadFile(path)) from calibration_workbench/optimizations/camera_intrinsic.h to load a ROS pinhole camera calibration with plumb_bob distortion. The result contains the camera name, image dimensions, intrinsics, and distortion coefficients.

The camera intrinsic application also reads this file from its configuration:

intrinsics_guess:
  ros_camera_info: cameras/camera.yaml

Use the same ros_camera_info entry under intrinsics in the hand-eye application. The intrinsic application also accepts intrinsics as an alias for intrinsics_guess. Paths are relative to the application configuration file. This entry replaces the inline fx, fy, cx, and cy fields. Both applications use these four pinhole values from the ROS camera matrix. The distortion and rectification values are omitted from the application's camera model.

Camera intrinsics after cropping or resizing

CameraIntrinsics::remapImageCoordinates returns calibration parameters in the new image coordinates. For an image cropped at (left, top) and then resized, pass (scale_x, scale_y, -scale_x * left, -scale_y * top). The principal point can lie outside the cropped image.

Run the hand-eye example

The example needs a graphical session. Keep the source checkout in place, because the example loads its dataset from a path recorded at build time.

source install/setup.bash
./install/calibration_workbench/lib/calibration_workbench/calibration_workbench_extrinsic_hand_eye

It runs against a modified circle grid and a ChArUco grid, prints the estimated transforms and analysis statistics, and displays the target points reprojected into the input images.

The bundled data is enough to run it without hardware. See examples/extrinsic_hand_eye.cpp for the source and examples/data/ for the datasets.

Run calibration without a display

Start either calibration application with --headless followed by its configuration, observation, and result files. The camera intrinsic application also accepts an optional ROS YAML output file. Append --observation-report report.csv to either command to save the observation report alongside the calibration result. Use a separate path for the report.

calibration_workbench_camera_intrinsic_calibration_app --headless config.yaml observations.yaml results.yaml ros-results.yaml
calibration_workbench_extrinsic_hand_eye_calibration_app --headless config.yaml observations.yaml results.yaml --observation-report report.csv

For intrinsic calibration, set use_extrinsic_guesses: false in the configuration file to use observations with an image entry and no pose entry. Hand-eye calibration and intrinsic calibration with extrinsic guesses require both files.

The applications exit after saving a converged result and report calibration errors to standard error.

Validate observations before calibration

Use --validate-only to check images and poses, detect features, and apply the calibration's homography threshold. The command writes the same observation-quality CSV as calibration.

calibration_workbench_camera_intrinsic_calibration_app --validate-only config.yaml observations.yaml report.csv
calibration_workbench_extrinsic_hand_eye_calibration_app --validate-only config.yaml observations.yaml report.csv

The command exits with 0 when it writes the report with at least one usable observation. If every observation is rejected, it writes the rejection reasons and exits with 1. Invalid or empty input and report-write errors also exit with 1. Validation does not solve a calibration or write result files.

Docker

A container definition and a Compose file are provided under docker/. The Compose file builds the image from this repository and mounts the X11 socket so the GUI applications can start.

cd docker
docker compose build
docker compose run --rm calibration_workbench

Inspect target detections

Read a target configuration and one image without opening a display. Pass a standalone target configuration or a calibration YAML with a target_finder entry. After sourcing the workspace environment, run:

./install/calibration_workbench/lib/calibration_workbench/calibration_workbench_detect_target \
  cal_data.yaml image.png > detections.csv

The default CSV contains feature_id,point_index,x,y with image coordinates in pixels. Use --overlay to save an annotated image and --correspondences to export matched 2D image points and 3D target points:

./install/calibration_workbench/lib/calibration_workbench/calibration_workbench_detect_target \
  cal_data.yaml image.png --overlay marked.png --correspondences > correspondences.csv

Use an image extension such as .png for the overlay and an output path different from the input files. Correspondence CSV columns are image_x,image_y,target_x,target_y,target_z. Image points are in pixels. Target points use the units defined in the target configuration. The command returns a nonzero status if detection fails or a requested output cannot be written.

Batch target diagnostics

Pass --batch after the target configuration, followed by one or more image paths:

./install/calibration_workbench/lib/calibration_workbench/calibration_workbench_detect_target \
  cal_data.yaml --batch 'frame "left", 01.png' 'frame right 02.png' > batch.csv

The CSV header is image_path,status,feature_count,point_count. Every input has one row, in argument order. Paths are quoted with embedded double quotes doubled. feature_count counts detected feature IDs and point_count counts all detected image points. Status is detected, no_detection, unreadable, or detector_error. A failed input has zero counts, and the command continues with the remaining inputs. Use --overlay and --correspondences in single-image mode.

Exit status is 0 when every image has detections, 1 when any image fails or a configuration or output error occurs, and 2 for invalid usage. A configuration error is reported before the command writes any CSV.

Documentation

Build an observation manifest

Create the observations YAML for a calibration application from an image directory. Add --poses to pair images with robot poses for hand-eye calibration or intrinsic calibration with extrinsic guesses:

prefix=install/calibration_workbench
dataset=/path/to/dataset
"$prefix/lib/calibration_workbench/calibration_workbench_make_observations" \
  "$dataset/images" --poses "$dataset/poses" --relative-to "$dataset" > "$dataset/observations.yaml"

The command writes data entries with an image path and, when requested, a pose path. The default paths are absolute. With --relative-to, save the manifest in the specified existing directory so the calibration applications can resolve the relative paths.

The scan includes regular files directly in each directory. Supported image suffixes are .bmp, .jpeg, .jpg, .pbm, .pgm, .png, .pnm, .ppm, .tif, .tiff, and .webp. Pose suffixes are .yaml and .yml. Suffix matching is case-insensitive. Image entries are sorted lexicographically by filename stem, and pose matching uses the exact, case-sensitive stem. The generator uses file names and leaves image and pose validation to the calibration application.

Exit status is 0 for a manifest, 1 for a directory, pairing, or output error, and 2 for invalid usage. Empty scans, duplicate stems, and missing pose matches produce a diagnostic on standard error before the command writes a manifest.

Export observation quality

In either calibration application, choose File → Export observation report to save the current observations as CSV. The report includes image and pose paths, detected feature counts, homography errors in pixels, and the status shown for each observation.

Estimate a target pose

Estimate the pose of a configured target in a single image without opening a display. Pass a standalone target configuration or a calibration YAML with a target_finder entry, a ROS plumb_bob camera calibration YAML, and an image of the calibrated resolution. The bundled ChArUco sample contains all three inputs:

source install/setup.bash
prefix=install/calibration_workbench
sample="$prefix/share/calibration_workbench/data/test_set_charuco"
"$prefix/lib/calibration_workbench/calibration_workbench_estimate_target_pose" \
  "$sample/cal_data.yaml" "$sample/camera.ros.yaml" "$sample/images/0.png" > pose.yaml

The YAML contains target_to_camera (translation x,y,z and quaternion qw,qx,qy,qz), correspondence_count, and reprojection_rms_px. The transform maps a target-frame point into the OpenCV camera optical frame (right, down, forward): p_camera = R * p_target + t. Translation uses the target's configured units. RMS is the root mean square Euclidean reprojection error per point in pixels, using the calibrated distortion coefficients.

Exit status is 0 for a pose, 2 for invalid command usage, and 1 for invalid inputs, insufficient target correspondences, or pose estimation or output failure. Input and estimation errors are reported to standard error before writing a result.

Contributing

See CONTRIBUTING.md.

License

Distributed under the Apache License, Version 2.0. The original copyright notice and the full license text are retained in LICENSE. Provenance and attribution are documented in NOTICE.

In accordance with section 4(b) of the License, modification notices are recorded in the repository history and in NOTICE.

About