Tools for the FNIRSI LCR-P1 component tester:
- A firmware patch for the stock v1.1.0 firmware that sends every reading over the meter's USB-C serial port, decodes many more infrared remotes, and lets the meter stay on longer.
- A Linux updater for FNIRSI's bootloader (replaces the Windows-only
BootTool.exe). lcrp1, a GTK4 / libadwaita app with live readings, history, CSV export and firmware update, pluslcrp1-logfor the terminal.
Not affiliated with FNIRSI. FNIRSI's firmware is not included: you download it from them and the build patches that exact file.
| Stock v1.1.0 | Patched (v1.1.0u) | |
|---|---|---|
| USB serial output | none | every line drawn on the screen (115200 8N1) |
| IR decoding | NEC only (32 bits, 68 edges max) | NEC, Samsung32, Sony SIRC 12/15/20, Gree/Kelvinator AC |
| AC remotes | first 4 bytes, as if NEC | first 4 bytes on screen + Long code - see PC; all 8 bytes over USB |
| Unknown remotes | nothing | raw mark/space timings over USB (IR raw <n>: …), up to 760 edges |
| Auto power-off | 60 s | 5 min (AUTOOFF_S), changeable from the PC: off … 60 min |
| Screen | white text, colour icons, FNIRSI boot logo | minimal purple theme: values purple, labels grey, symbols and icons purple, pin legend as plain grey digits, boot picture (horned mask or skull) |
| PC control | none | run a test, auto-repeat tests, auto power-off, power off (USB serial commands) |
| Low-battery shutdown | ~3.5 V | 3.4 V (LOWBAT_MV, 3.3 – 3.6 V) |
Measurement code is untouched. The image is the same size as stock and keeps the stock calibration code.
Tested on a real LCR-P1: resistors and capacitors read the same as with stock firmware; NEC (LG codes from a Google TV remote), Samsung TV and Gree-type AC remotes decode on the meter. Sony is tested in the emulator only so far. Serial commands tested on the meter: status, remote test, auto-repeat, auto power-off.
Needs arm-none-eabi-gcc / binutils and Python 3.
- Download LCR-P1 Firmware v1.1.0 from FNIRSI and put
APP_LCR-P1-EN_V1.1.0_260324.BINinfw/. - Build:
The build checks the stock file's SHA-256 and every patched location before changing it.
python3 firmware/make_patch.py # -> build/APP_LCR-P1-EN_V1.1.0u.BIN AUTOOFF_S=600 LOWBAT_MV=3500 python3 firmware/make_patch.py # other settings BOOT_ART=skull python3 firmware/make_patch.py # other boot picture (firmware/art/*.py, 32x32) PIN_DEBUG=1 python3 firmware/make_patch.py # diagnostic build: logs GPIO changes (see docs/NOTES.md)
- Optional, run the emulator tests (they drive the patched code with real IR recordings):
python3 -m venv .venv && .venv/bin/pip install unicorn ./firmware/run_tests.sh
On the meter: hold ZENER, then press TEST to enter update mode. Then either use the app (menu → Update Firmware…) or:
PYTHONPATH=app python3 -m lcrp1 flash build/APP_LCR-P1-EN_V1.1.0u.BIN # or: lcrp1 flash … once installedUpdate successful (reply ac 55 03 04) means done; the meter restarts. To go back, flash FNIRSI's stock
file the same way. The bootloader is not touched by updates, so update mode always works.
Calibration. The stock and patched images reach 0x0800FF8C, so their last 512-byte block also rewrites
the flash page holding the meter's calibration record (dEnK at 0x0800FFD0). FNIRSI's loader does not
keep it, and neither does the LCR-P1 bootloader. After such an update the meter asks for the short-connector
calibration again. Images that end lower, such as lcrp1-fw, leave that page alone. Run
lcrp1 flash --backup first if the LCR-P1 bootloader is installed.
With the LCR-P1 bootloader installed, the same
command uses its checked protocol: CRC per frame, verify per page, and an image CRC check before the app
can start. If the meter runs lcrp1-fw, the flasher sends #U to switch it to update mode, so no keys are
needed. Extra options:
lcrp1 flash --baud 460800 lcrp1-fw.bin # faster link
lcrp1 flash --backup flash-backup.bin # read all 64 KB (bootloader, app, calibration)Your user needs access to the serial port (uucp group on Arch, dialout on Debian/Ubuntu).
./app/install.sh # ~/.local/bin/lcrp1, lcrp1-log, launcher entry "LCR-P1 Component Tester"
./app/install.sh --uninstall- Finds the meter's CH340 by itself and reconnects when the meter is switched off and on.
- Latest result in large type (
360.6 Ω,988.0 kΩ, IR codes, full AC code), history, CSV export. - Bottom bar: Test, Repeat every n s, Auto-off after n min, power off.
- Update Firmware… checks the file, then flashes with a progress bar.
lcrp1 --replay capture.txtshows a saved raw capture without a meter.
lcrp1-log [--csv out.csv] [--jsonl out.jsonl] [--raw raw.txt] prints one line per measurement:
2026-11-13 20:29:44 Resistance pins 1-2 value=360.5ohm
2026-11-13 20:20:51 IR protocol=NEC address=0x04FB command=0x02FD
2026-11-13 20:20:45 IR protocol=Gree AC power=on mode=cool temp_C=24 fan=0 light=on bytes=09 08 60 50 00 C0 00 70
The Gree field names (mode, temperature, …) are a best guess from the Gree layout; the bytes are exact.
The patched firmware also listens on the USB serial port. A command is # + letter (+ number) + newline;
the meter answers #<letter> R=<repeat s> A=<auto-off s> P=<1 on the IR page>.
The meter's USART holds a single received byte and the firmware reads it once per main-loop pass, so send
one byte at a time: the meter echoes each byte with bit 7 set (byte | 0x80), send the next one after
that echo. lcrp1, lcrp1 cmd and lcrp1-log --send do this for you. Auto power-off counts idle time since
the last key press or test, not since the command.
| Command | |
|---|---|
#T |
run a test, exactly as pressing TEST (ignored on the IR page, like the button) |
#R<s> |
test again s seconds after the previous test finished; #R0 off. A real key press restarts the wait |
#A<s> |
auto power-off after s idle seconds; #A0 off (the meter still switches off after 60 min) |
#O |
switch off now |
#? |
status |
Settings are kept until the meter is switched off. From the shell: lcrp1 cmd T, lcrp1 cmd R3 A0, or
log hands-free: lcrp1-log --send R3 --csv parts.csv and insert parts one after another. The app has the same
controls in its bottom bar.
See docs/NOTES.md: memory map, the bootloader's update protocol, every patch point, and what was learned on the way (including why the firmware's debug prints must stay).
MIT for the code in this repository. FNIRSI's firmware and tools are theirs and are not distributed here.