Repository navigation
Link published MININET-SDN appliance and repair student setup - #1
Merged
Merged
Conversation
Record the reserved appliance DOI and verified identity metadata, distinguish VirtualBox and WSL routes, correct Portainer failure handling and repair the S06 OS-Ken policy and OVS verification contracts. Publication remains pending. Native appliance and Windows acceptance are separate from the source checks and isolated regression tests.
Record the publication state reported by the supplied Zenodo export, retain the version-specific DOI and checksum, and distinguish the concept DOI. Update current download guidance and add an appliance citation while preserving the earlier preparation history.
antonioclim
marked this pull request as ready for review
November 16, 2026 20:45
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
Why this change is needed
Students need a consistent route from COMPNET-EN to the published MININET-SDN appliance and setup instructions that match the repository. The previous instructions contained obsolete paths, mismatched Compose commands and host/guest assumptions. Portainer setup could report success after authentication or endpoint errors, while the advanced S06 controller and OVS checker had reproducible correctness defects.
What changes
Current student-facing instructions describe the published release. The changelog preserves the earlier preparation state and adds the publication follow-up. The original institutional installer and repository licence terms are unchanged.
Validation
eaf4fdcdc387c74da997d0324968b5f002df12d4: both pull-request CI and push CI succeeded. The PR job reports 68 pytest tests passed.Evidence and limits
The author confirms that he built, configured and tested the OVA used in the ASE labs. The publication state, version DOI and concept DOI are supported by his supplied published Zenodo record export. Independent HTTP retrieval of the Zenodo/DOI endpoints was unavailable through the review environment's web tool; no successful live download check is claimed.
No OVA bytes were available for an independent hash computation. Native Windows PowerShell, WSL, VirtualBox, Docker and Mininet acceptance was not performed in this source review. HTML structure and commands were checked, while visual rendering was blocked by the browser runtime.
The dependency bound is a compatibility safeguard, not a complete environment lockfile. The committed regression tests are in
00_TOOLS/qa/test_mininet_setup_contracts.py.