4 changes: 4 additions & 0 deletions .gitattributes
Original file line number Diff line number Diff line change
@@ -1,2 +1,6 @@
# Canonical text evidence must retain its original bytes.
sources/myhome-suite/3.5.38/support/OpenQuery.txt -text

# Machine KB artifacts and fixtures require deterministic LF endings.
*.jsonl text eol=lf
knowledge/** text eol=lf
7 changes: 7 additions & 0 deletions device-model/physical-devices.md
Original file line number Diff line number Diff line change
Expand Up @@ -96,6 +96,7 @@ The interpretation is supported by Devices whose physical configuration layouts
| --- | ---: | --- |
| `F420` | `2` | 2 |
| `F429` | `3` | 3 (`A`, `G`, `M`) |
| `LN4660M2` | `6` (corroborated) | 6 (`A`, `PL`, `Ar`, `PLr`, `M`, `Pre`) |
| `H4652/3` | `7` | 7 |

The correspondence across Devices with different values argues against interpreting ordinary addressed-form `N_CONF` as a Module count or general Device classification. In that corroborated scope, it describes the size of the Device's physical configurator interface.
Expand Down Expand Up @@ -149,6 +150,12 @@ SKU `F418U2` resolves to item `2065`, “2x1,6A universal dimmer, 4DIN”, and f

SKU `3476` is a one-slot Basic control actuator. SKU `3477` is a two-slot Basic contacts interface whose Modules can expose contact-state and command functions. Similar physical installation style therefore does not imply the same logical composition.

### `LN4660M2`, `H4660M2`, `AM5860M2`, and `067558`

These four SKUs (Livinglight `LN4660M2`, Axolute `H4660M2`, Matix `AM5860M2`, and Céliane `067558`) share item `1579`, “Shutter control bus”, item model `46`, and firmware `205`. The firmware exposes a single slot containing Object `529` (“Shutter control”), belonging to family `1` (Control).

The hardware interface provides six physical configurator positions (`A`, `PL`, `Ar`, `PLr`, `M`, and `Pre`), corroborating `N_CONF = 6` for this device family from independent installation documentation rather than directly observed on-wire diagnostic responses. When configured with `A=GEN`, the device acts as a centralized automation control broadcasting Advanced Automation commands to the General scope (`WHERE = 0`). The `Ar` and `PLr` sockets assign a reference actuator for state synchronization and preset management, while `M` sets operation modality and `Pre` selects the preset index. No actuator output is exposed by this item.

## Dependent Devices and interfaces

The catalogue contains additional Device-level associations:
Expand Down
8 changes: 7 additions & 1 deletion functional/who-2-automation/addressing.md
Original file line number Diff line number Diff line change
Expand Up @@ -31,4 +31,10 @@ Commands addressed to a group, environment, or the general scope can produce eve

The MyHOME_Suite `OPEN.db` address-rule definitions represent the same `A`/`PL` address family through system-specific point-to-point, environment, and advanced rules.

See [`WHAT` Reference](what.md) for movement commands, [`DIMENSION` Reference](dimensions.md) for advanced shutter state/position data, and [Addressing](../../protocol/addressing.md) for the common system-scoped addressing model.
## Centralized transmitters and General scope

Centralized control devices configured with `A=GEN` target the General scope (`WHERE = 0`). In the referenced MyHomeServer1/LN4660M2 captures, the observed movement frame used the event-style form `*2*11#100#001#1*0##`.

Because OpenWebNet command frames carry only the target address rather than the originator address, frames with `WHERE = 0` do not identify which physical transmitter generated the command. In the [public MyHomeServer1/LN4660M2 traces](https://github.com/OpenWebNet-HA/MyHOME/tree/198a848e73edd2a887b993b98beffa98f3f20e36/tests/fixtures/traces/issue_445), the centralized operation was followed by individual point-to-point `DIMENSION 10` status reports from affected actuators on their respective `A`/`PL` addresses. Treat that telemetry sequence as observed behavior for the captured gateway/controller path rather than a universal requirement for every gateway implementation.

See [`WHAT` Reference](what.md) for movement commands, [`DIMENSION` Reference](dimensions.md) for advanced shutter state/position data, and [Addressing](../../protocol/addressing.md) for the common system-scoped addressing model.
53 changes: 48 additions & 5 deletions functional/who-2-automation/what.md
Original file line number Diff line number Diff line change
Expand Up @@ -14,13 +14,13 @@ Collective commands can expand into events for the addressed scope and the indiv

## Advanced commands

| Leading `WHAT` | Function | Parameters |
| Leading `WHAT` | Function | Command parameters |
| ---: | --- | --- |
| `10` | Advanced Stop | priority; set/clear selector |
| `11` | Advanced Up | optional step; priority; set/clear selector |
| `12` | Advanced Down | optional step; priority; set/clear selector |
| `10` | Advanced Stop | priority |
| `11` | Advanced Up | optional step; priority |
| `12` | Advanced Down | optional step; priority |

The exact `#`-parameterized form is part of `WHAT`; parsing only the leading number loses the requested step and priority operation.
Event-session forms append the set/clear selector described below. The exact `#`-parameterized form is part of `WHAT`; parsing only the leading number loses the requested step and priority operation.

### Step

Expand All @@ -30,6 +30,49 @@ The exact `#`-parameterized form is part of `WHAT`; parsing only the leading num

The priority payload contains a set/clear selector and Safety, High, and Medium flags. A zero flag leaves that priority unchanged. This is a bit-selection operation, not a single ordinal priority number.

### Parameter format

The published [`WHO 2` specification](../../sources/openwebnet-public/pdf/WHO_2.pdf) defines separate parameter structures for command sessions and event sessions:

**Published command session grammar** (client to server):
~~~text
*2*10#PRIORITY*WHERE## (Advanced Stop)
*2*11#STEP#PRIORITY*WHERE## (Advanced Up)
*2*12#STEP#PRIORITY*WHERE## (Advanced Down)
~~~

Where:
- `STEP`: `1..99` specifies a relative step percentage; `100` (or omitted/null) requests movement to the physical endpoint (full open or full close).
- `PRIORITY`: 3-digit bitfield (`p1 p2 p3`) representing Safety (`p1`), High (`p2`), and Medium (`p3`) priority levels (for example, `001` sets standard medium priority).

**Published event session grammar** (server to client):
In event sessions and status reports, the server appends a selector flag (`<shutterType>`):
~~~text
*2*10#PRIORITY#SELECTOR*WHERE## (Advanced Stop event)
*2*11#STEP#PRIORITY#SELECTOR*WHERE## (Advanced Up event)
*2*12#STEP#PRIORITY#SELECTOR*WHERE## (Advanced Down event)
~~~

Where `SELECTOR`:
- `0`: Clear priority.
- `1`: Set priority.

Command-translation reports (`WHAT 1000`) for point targets wrap this event structure: `*2*1000#11#PRIORITY#SELECTOR*WHERE##`.

**Observed physical transmitter frames**:
In the referenced MyHomeServer1/LN4660M2 captures, the physical centralized controller broadcasting to the General scope (`WHERE = 0`) emitted the event-style multi-parameter form with `SELECTOR = 1` (Set priority) directly onto the SCS bus:
- Up: `*2*11#100#001#1*0##`
- Down: `*2*12#100#001#1*0##`
- Stop: `*2*10#001#1*0##`

This on-wire behavior is corroborated by authentic bus monitor traces captured on a physical MyHomeServer1 gateway with an `LN4660M2` centralized controller ([public MyHomeServer1/LN4660M2 traces](https://github.com/OpenWebNet-HA/MyHOME/tree/198a848e73edd2a887b993b98beffa98f3f20e36/tests/fixtures/traces/issue_445), contributed by Francesco Montorsi on [MyHOME issue #445](https://github.com/OpenWebNet-HA/MyHOME/issues/445) and [#466 (comment 5853591733)](https://github.com/OpenWebNet-HA/MyHOME/issues/466#issuecomment-5853591733)).

### Physical transmitter STOP / PRESET behavior

Advanced physical shutter controls (such as `LN4660M2`, `H4660M2`, `AM5860M2`) feature a dual-function middle button:
- When shutters are **in motion**: pressing the button invokes Advanced Stop. In the referenced LN4660M2 capture, this appeared on the bus as the event-style frame `*2*10#001#1*0##`.
- When shutters are **stationary**: pressing the button triggers the **PRESET** function, recalling a pre-configured intermediate position stored within the actuators.

## Command-translation reports - `WHAT 1000`

The published Automation flows use `1000#INNER_WHAT...` when reporting translated commands for point targets. Base operations can appear as:
Expand Down