fix(heating): keep dimension 7 write echoes typeless in OWNEvent - #62

Merged
GreenGrassBlueOcean merged 1 commit into
OpenWebNet-HA:masterfrom
GreenGrassBlueOcean:fix/heating-dim7-write-echo
Sep 25, 2026
Merged

GreenGrassBlueOcean merged 1 commit into
OpenWebNet-HA:masterfrom
GreenGrassBlueOcean:fix/heating-dim7-write-echo

Conversation

@GreenGrassBlueOcean

Copy link
Copy Markdown
Contributor

Follow-up to #60 addressing review remarks from @fedem95 (#60 (review)).

Summary of changes

  1. Keep DIMENSION 7 write echoes typeless across entry points:

    • In OWNHeatingEvent, skip the dimension 7 block when _message_type == "DIMENSION_WRITING".
    • When parsing a program write echo (e.g. *#4*2*#7*1*1*0170##), OWNEvent.parse and direct OWNHeatingEvent construction now stay typeless (message_type is None, with unset zone_context, zone_state, and set_temperature), agreeing with OWNMessage.parse which returns an OWNHeatingCommand.
    • Added test_dimension_7_write_echo_stays_typeless_across_entry_points to verify this behavior across both entry points and direct construction.
  2. Clarify test fixture provenance comments:

    • Updated the comment block and docstrings in tests/test_heating.py to explicitly distinguish verbatim bus capture frames (from xtimmy86x and TheDarkWizard in MyHOME#429) from synthetic edge cases (unknown context/state codes, missing state, malformed temperatures, and ScenarioDevices write templates).

Verification

  • OWNd test suite: 838 passed, 1 skipped.
  • Linters & standards: ruff, mypy, and scripts/verify_library_standards.py clean.
  • MyHOME test suite: 2082 passed, 1 skipped against this branch.

- Skip the dimension 7 branch in OWNHeatingEvent when _message_type is 'DIMENSION_WRITING', ensuring write echoes (*OpenWebNet-HA#4*Z*OpenWebNet-HA#7*...##) remain typeless when parsed via OWNEvent.parse or direct OWNHeatingEvent construction, agreeing with OWNMessage.parse.

- Add test_dimension_7_write_echo_stays_typeless_across_entry_points verifying consistent typeless behavior across entry points.

- Clarify comments and docstrings in tests/test_heating.py to explicitly distinguish real bus capture fixtures from synthetic edge cases (unknown codes, missing state, malformed temperatures, and ScenarioDevices templates).
@codecov-commenter

Copy link
Copy Markdown

⚠️ Please install the 'codecov app svg image' to ensure uploads and comments are reliably processed by Codecov.

Codecov Report

✅ All modified and coverable lines are covered by tests.

📢 Thoughts on this report? Let us know!

@fedem95 fedem95 left a comment

Copy link
Copy Markdown
Contributor

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Both points from #60 are in, thanks.*#4*2*#7*1*1*0170## and *#4*2*#7*2*3*## now stay typeless through OWNEvent.parse too, while OWNMessage.parse still gives the readable OWNHeatingCommand, and the real dimension 7 status *#4*2*7*1*1*0170## still decodes to heating setpoint 17.0 °C on both. The test comments now separate the #429 captures from the synthetic cases.

Approving.

@GreenGrassBlueOcean
GreenGrassBlueOcean merged commit 6002fd8 into OpenWebNet-HA:master Sep 25, 2026
8 checks passed