Skip to content

Fix double increment of sequence number - #11

Merged
FLo-ABB merged 2 commits into
FLo-ABB:mainfrom
albsve2:fix-seqno-double-increment
Oct 26, 2026
Merged

FLo-ABB merged 2 commits into
FLo-ABB:mainfrom
albsve2:fix-seqno-double-increment

Conversation

@albsve2

@albsve2 albsve2 commented Oct 26, 2026

Copy link
Copy Markdown
Contributor

The sequence number was incremented both in send_to_robot / send_to_robot_cart and inside _create_sensor_message*, so the header seqno went 1, 3, 5... send_to_robot_path_corr already increments only once. This removes the extra increment so the sequence is 0, 1, 2...

Verified by sending three messages to a local UDP socket and reading back header.seqno: before the fix [1, 3, 5], after [0, 1, 2]. Happy to add the test to the repo if you'd like.

@FLo-ABB
FLo-ABB merged commit 2437670 into FLo-ABB:main Oct 26, 2026
2 checks passed
@FLo-ABB

FLo-ABB commented Oct 26, 2026

Copy link
Copy Markdown
Owner

Thank to pointing this out and fixing it. I appreciate

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment