Repository navigation
Fix double increment of sequence number - #11
Merged
Merged
Conversation
Owner
|
Thank to pointing this out and fixing it. I appreciate |
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
The sequence number was incremented both in
send_to_robot/send_to_robot_cartand inside_create_sensor_message*, so the headerseqnowent 1, 3, 5...send_to_robot_path_corralready increments only once. This removes the extra increment so the sequence is 0, 1, 2...Verified by sending three messages to a local UDP socket and reading back
header.seqno: before the fix [1, 3, 5], after [0, 1, 2]. Happy to add the test to the repo if you'd like.