Skip to content

Read ProfileInfo flags as bytes instead of bool - #582

Merged
slabko merged 1 commit into
ClickHouse:masterfrom
iliaal:fix/profileinfo-bool
Oct 28, 2026
Merged

slabko merged 1 commit into
ClickHouse:masterfrom
iliaal:fix/profileinfo-bool

Conversation

@iliaal

@iliaal iliaal commented Oct 18, 2026

Copy link
Copy Markdown
Contributor

Client::Impl::ReceiveProfileInfo reads the applied_limit and calculated_rows_before_limit wire bytes directly into bool members. A byte other than 0 or 1 leaves a bool holding an invalid value, and loading it is undefined behaviour. UBSan reports "load of value 5, which is not a valid value for type 'bool'" in OnProfile callbacks, and an optimized build can misbehave.

Fix: read each flag into a uint8_t and store whether it is non-zero. The obsolete has_nested byte in ReceiveException gets the same treatment. No other wire read lands directly in a bool.

Reproducer: a ProfileInfo packet whose applied_limit byte is 0x05.

Test: ClientProtocol.ProfileInfoFlagsAcceptAnyNonZeroByte sends bytes 5 and 255. It fails on master and passes here.

@iliaal
iliaal requested review from mzitnik and slabko as code owners October 18, 2026 16:44
slabko
slabko previously approved these changes Oct 28, 2026
Client::Impl::ReceiveProfileInfo read the applied_limit and
calculated_rows_before_limit wire bytes directly into bool members. A byte
other than 0 or 1 left a bool with an invalid value, and loading it is
undefined behaviour (UBSan reports it in OnProfile callbacks). Read each flag
into a uint8_t and store whether it is non-zero; the obsolete has_nested byte
in ReceiveException gets the same treatment.
@slabko
slabko merged commit c1ddc7a into ClickHouse:master Oct 28, 2026
45 checks passed