From 07869eb239ba6c34cccd17f2c947ccc3cb278c21 Mon Sep 17 00:00:00 2001 From: Jeff Verkoeyen Date: Sun, 1 Nov 2026 19:40:19 -0500 Subject: [PATCH] Poll fuel level every second Fuel level commands polled every 5 to 60 seconds; they now poll every second, as the app polls the standard 012F fuel level. --- signalsets/v3/default.json | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/signalsets/v3/default.json b/signalsets/v3/default.json index 6660721..738bc62 100644 --- a/signalsets/v3/default.json +++ b/signalsets/v3/default.json @@ -169,7 +169,7 @@ "signals": [ {"id": "RX_ATF_T_PAN_V3", "path": "Transmission", "fmt": { "len": 16, "max": 215, "min": -40, "div": 256, "add": -40, "unit": "celsius" }, "name": "Transmission fluid temperature, pan var.3", "suggestedMetric": "transmissionFluidTemperature"} ]}, -{ "hdr": "700", "rax": "708", "cmd": {"22": "1F2F"}, "freq": 30, "filter": { "from": 2016 }, "dbgfilter": { "to": 2019, "years": [2021], "from": 2023 }, +{ "hdr": "700", "rax": "708", "cmd": {"22": "1F2F"}, "freq": 1, "filter": { "from": 2016 }, "dbgfilter": { "to": 2019, "years": [2021], "from": 2023 }, "signals": [ {"id": "RX_FLI", "path": "Fuel", "fmt": { "len": 8, "max": 100, "mul": 100, "div": 255, "unit": "percent" }, "name": "Fuel level", "suggestedMetric": "fuelTankLevel"} ]},